<?xml version="1.0" encoding="UTF-8"?>
<article article-type="research-article" dtd-version="1.3" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group>
        <journal-title>Czech and Slovak Ophthalmology</journal-title>
      </journal-title-group>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id">36</article-id>
      <article-categories>
        <subj-group>
          <subject>Original article</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Uncorrected near visual acuity after monofocal intraocular lens implantation</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Lešták</surname>
            <given-names>Ján</given-names>
          </name>
          <contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-9630-3441</contrib-id>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Pitrová</surname>
            <given-names>Šárka</given-names>
          </name>
          <contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-8472-9234</contrib-id>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Fůs</surname>
            <given-names>Martin</given-names>
          </name>
          <contrib-id contrib-id-type="orcid">https://orcid.org/0000-0003-3245-4544</contrib-id>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Žáková</surname>
            <given-names>Markéta</given-names>
          </name>
        </contrib>
      </contrib-group>
      <pub-date date-type="pub" publication-format="electronic">
        <day>30</day>
        <month>8</month>
        <year>2017</year>
      </pub-date>
      <issue>4</issue>
      <elocation-id>1</elocation-id>
      <abstract>
        <p>Aim of the study was to evaluate retrospectively selected parameters, which influence the postoperative near visual acuity in a group of pseudophakic eyes of patients with Uncorrected Distance Visual Acuity (UDVA) and according to acquired results establish those, which mostly influenced good Uncorrected Near Visual Acuity (UNVA) after the implantation of monofocal IntraOcular Lens (IOL). Altogether, 122 pseudophakic eyes of 65patients were followed up, out of them in 57 patients both eyes were operated on. The frequency of visual acuity for three groups of operated eyes categorized according to the crucial parameter – eye’s axial length (short, average, long) was evaluated. In each of groups, the average parameters (age, axial length, keratometry, and depth of the anterior chamber) were established, as well as relative frequency of postoperative uncorrected near visual acuity on conventionally used reading tables. The near visual acuity assessment for each eye separately was preformed in its horizontal position using the Zeiss table. The study did not confirm positive correlation of postoperative near visual acuity on the age of the patient, depth of the anterior chamber, nor the implanted IOL type. It was confirmed the presumption of optimal near visual acuity for eyes with axial length shorter than 23.5 mm, and in the process, between both parameters slightly negative correlation was found. On the other hand, middle positive correlation between uncorrected near visual acuity and central corneal power (in dioptres) in eyes with the axial length 22.5 – 23.5 mm was found. The study confirmed, that higher values of the central corneal power (in dioptres) and the high borderline value of the axial length up to 23.5 mm are the condition for optimal postoperative uncorrected near visual acuity after the implantation of monofocal intraocular lens.</p>
      </abstract>
      <kwd-group>
        <kwd>Uncorrected Near Visual Acuity (UNVA)</kwd>
        <kwd>monofocal intraocular lens</kwd>
        <kwd>pseudoaccommodation</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <back>
    <ref-list>
      <title>References</title>
      <ref id="R8907">
        <mixed-citation>Nawa, Yioshiaky et al.: Accommodation obtained per 1.0 mm forward movement of a posterior chamber intraocular lens. Journal of Cataract &amp; Refractive Surgery, 29(11); 2003: 2069–2072.</mixed-citation>
      </ref>
      <ref id="R8908">
        <mixed-citation>Lim, Dong Hui, Jong Chul Han, Myung Hun Kim, Eui-Sang Chung, Tae-Young Chung: Factors Affecting Near Vision After Monofocal Intraocular Lens Implantation. Journal of Refractive Surgery, 29(3); 2013: 200–204.</mixed-citation>
      </ref>
      <ref id="R8909">
        <mixed-citation>Hayashi, Ken, Hideyuki Hayashi, Fuminori Nakao, Fumihiko Hayashi.: Aging changes in apparent accommodation in eyes with a monofocal intraocular lens. American Journal of Ophthalmology, 135(4); 2003 432–436.</mixed-citation>
      </ref>
      <ref id="R8910">
        <mixed-citation>Nanavaty, Mayank A., Abhay R. Vasavada, Anil S. Patel, Shetal M. Raj, Tejas H. Desai: Analysis of patients with good uncorrected distance and near vision after monofocal intraocular lens implantation. Journal of Cataract &amp; Refractive Surgery, 32( 7); 2006: 1091–1097.</mixed-citation>
      </ref>
      <ref id="R8911">
        <mixed-citation>Leyland, M, Edward Pringle E.: Multifocal versus monofocal intraocular lenses after cataract extraction. Cochrane Database of Systematic Reviews [online]. Chiches- Feasibility of multifocal intra-ocular lens exchange and conversion to the bag-in the-lens implantation. Acta Opohthalmol, 92; 2014: 256–259.</mixed-citation>
      </ref>
      <ref id="R8912">
        <mixed-citation>MESCI, Cem, Hasan Hasbi ERBIL, Ali OL- GUN a Sevil Ari YAYLALI. Visual Performances with Monofocal, Accommodating, and Multifocal Intraocular Lenses in Patients With Unilateral Cataract. American Journal of Ophthalmology, 150(5); 2010: 609–618.</mixed-citation>
      </ref>
      <ref id="R8913">
        <mixed-citation>Heatley, Catherine J., David J. Spalton, Jo Hancox, Anupma Kumar, John Marshall: Fellow Eye Comparison Between the 1CU Accommodative Intraocular Lens and the Acrysof MA30 Monofocal Intraocular Lens. American Journal of Ophthalmology, 140(2); 2005: 207.e1–207.e8.</mixed-citation>
      </ref>
      <ref id="R8914">
        <mixed-citation>De Vries, Niels E., Carroll A.B. Webers, Wouter R.H., Touwslager, Noel J.C. Bauer, John De Brabander, Tos T. Berendschot, Rudy M.M.A. Nuijts: Dissatisfaction after implantation of multifocal intraocular lenses. Journal of Cataract &amp; Refractive Surgery, 37(5); 2011, 859–865.</mixed-citation>
      </ref>
      <ref id="R8915">
        <mixed-citation>Tassignon MJ, Bartholomeeusen E, Rozema JJ, Jongenelen S, Mathysen DG:</mixed-citation>
      </ref>
      <ref id="R8916">
        <mixed-citation>Cochener B, Lafuma A, Khoshnood B, Courouve L, Berdeaux G: Comparison of outcome with multifocal intraocular lenses: a meta-analysis. Clinical Ophthalmology, 5; 2011: 45–56.</mixed-citation>
      </ref>
      <ref id="R8917">
        <mixed-citation>Marešová K, Mlčák P, Vláčil O: Výsledky operací katarakty s implantací Acrysof Restor SN6AD3. Čes a Slov. Oftal, 66 (1); 2010: 26–28.</mixed-citation>
      </ref>
      <ref id="R8918">
        <mixed-citation>Urminský J, Rozsíval P, Feuermannová A, Lorencová V, Jirásková N: Implantace multifokální nitrooční čočky. Čes a Slov Oftal, 60 (1); 2004: 30–36.</mixed-citation>
      </ref>
      <ref id="R8919">
        <mixed-citation>Brožková M, Filipec M, Filipová L, Holubová A, Hlinomazová Z: Výsledky implantace trifokální torické čočky u pacientů s kataraktou. Čes a Slov Oftal, 72 (3); 2016: 58–64.</mixed-citation>
      </ref>
      <ref id="R8920">
        <mixed-citation>Veliká V, Hejsek L, Raiskup F: Klinické vý - sledky implantace dvou typů multifokální rotačně asymetrické nitrooční čočky. Čes a Slov Oftal, 73 (1); 2017: 3–12.</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>