<?xml version="1.0" encoding="UTF-8"?>
<article article-type="research-article" dtd-version="1.3" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group>
        <journal-title>Czech and Slovak Ophthalmology</journal-title>
      </journal-title-group>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id">533</article-id>
      <article-categories>
        <subj-group>
          <subject>Original article</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Evaluation of the Clinical Results of Implantation the Hydrophobic-hydrophilic Intraocular Lens ERIFLEX 877 FAB</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Stěpanov</surname>
            <given-names>Alexandr</given-names>
          </name>
          <contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-8462-8756</contrib-id>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Jirásková</surname>
            <given-names>Naďa</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Nekolová</surname>
            <given-names>Jana</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Lackovič</surname>
            <given-names>Jan</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Románek</surname>
            <given-names>Jaroslav</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Rozsíval</surname>
            <given-names>Pavel</given-names>
          </name>
          <contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-6628-7954</contrib-id>
        </contrib>
      </contrib-group>
      <pub-date date-type="pub" publication-format="electronic">
        <day>2</day>
        <month>12</month>
        <year>2013</year>
      </pub-date>
      <issue>6</issue>
      <elocation-id>2</elocation-id>
      <abstract>
        <p>Purpose: To evaluate the properties of intraocular lens ERIFLEX 877 FAB, the manipulation during implantation and clinical outcomes after implantation of the new hydrophobic-hydrophilic intraocular lens in patients undergoing routine cataract surgery. Material and Methods: The study included 30 patients (38 eyes), mean age 71 ± 8 years (range 53–89 years) with senile cataract. After phacoemulsification intraocular lens ERIFLEX 877 FAB was implanted. Patients were evaluated at 3 months after surgery. We assessed the uncorrected visual acuity (UCVA) and best corrected visual acuity (BCVA), refraction, keratometry and the incidence of posterior capsule opacification (PCO - Posterior capsule opacification). Individual patient’s and surgeon’s satisfaction was also documented including manipulation during surgery. Results: Three months after surgery, the mean UCVA was 0.7 ± 0.2 and BCVA was 0.97 ± 0.16. PCO value was 0.15 ± 0.09, that means minimal incidence of PCO. Good UCVA and a minimal incidence of PCO have resulted in a high degree satisfaction of patients. Conclusion: The new hydrophobic-hydrophilic intraocular lens ERIFLEX 877 FAB could be easily implanted and after surgery shows a high degree of biocompatibility in patients undergoing routine cataract surgery.</p>
      </abstract>