<?xml version="1.0" encoding="UTF-8"?>
<article article-type="research-article" dtd-version="1.3" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group>
        <journal-title>Czech and Slovak Ophthalmology</journal-title>
      </journal-title-group>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id">91</article-id>
      <article-id pub-id-type="doi">10.31348/2018/1/4-6-2018</article-id>
      <article-categories>
        <subj-group>
          <subject>Original article</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>The Effect of Multiple Variables on the Refractive Error After Cataract Surgery</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Popov</surname>
            <given-names>Ivajlo</given-names>
          </name>
          <contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-6368-0347</contrib-id>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Valášková</surname>
            <given-names>Jela</given-names>
          </name>
          <contrib-id contrib-id-type="orcid">https://orcid.org/0009-0002-4740-2587</contrib-id>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Krásnik</surname>
            <given-names>Vladimír</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Tomčíková</surname>
            <given-names>Dana</given-names>
          </name>
          <contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-9285-7065</contrib-id>
        </contrib>
      </contrib-group>
      <pub-date date-type="pub" publication-format="electronic">
        <day>18</day>
        <month>3</month>
        <year>2019</year>
      </pub-date>
      <issue>4</issue>
      <elocation-id>6</elocation-id>
      <abstract>
        <p>Purpose: To analyze refractive results after cataract surgery in relation to used type of monofocal intraocular lens, calculation formula, to age, gender and laterality. Settings: Department of Ophthalmology, Comenius University and University hospital in Bratislava, Slovakia Methods: We analyzed 173 eyes (118 patients) after uneventful cataract surgery. We calculated prediction error (PE) and mean absolute error (MAE) of postoperative refraction. Results and conclusion: We found no statistically significant differences in PE and MAE in relation to types of used IOL, calculation formulas, gender, age or laterality.</p>
      </abstract>
      <kwd-group>
        <kwd>Optical biometry</kwd>
        <kwd>monofocal IOL</kwd>
        <kwd>IOL calculation</kwd>
        <kwd>refractive error</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <back>
    <ref-list>
      <title>References</title>
      <ref id="R7932">
        <mixed-citation>Apple, D.J., J. Sims: Harold Ridley and the invention of the intraocular lens. Surv Ophthalmol, 40(4); 1996: 279-92.</mixed-citation>
      </ref>
      <ref id="R7933">
        <mixed-citation>Lundstrom, M., M. Dickman, Y. Henry, et al.: Risk factors for refractive error after cataract surgery: Analysis of 282 811 cataract extractions reported to the European Registry of Quality Outcomes for cataract and refractive surgery. J Cataract Refract Surg, 44(4); 2018: 447-452.</mixed-citation>
      </ref>
      <ref id="R7934">
        <mixed-citation>Popov, I., Valaskova J., Stefanickova J., et al.: Výpočet zastúpenia refrakčných chýb slovenskej populácie za použitia gullstrandovho modelu oka. Cesk Slov Oftalmol, 73(3); 2017: 113-117.4. Roessler, G.F., T.S. Dietlein, N. Plange, et al.: Accuracy of intraocular lens power calculation using partial coherence interferometry in patients with high myopia. Ophthalmic Physiol Opt, 32(3); 2012: 228-33.</mixed-citation>
      </ref>
      <ref id="R7935">
        <mixed-citation>Fotedar, R., J.J. Wang, G. Burlutsky, et al.: Distribution of axial length and ocular biometry measured using partial coherence laser interferometry (IOL Master) in an older white population. Ophthalmology, 117(3); 2010: 417-23.</mixed-citation>
      </ref>
      <ref id="R7936">
        <mixed-citation>Kane, J.X., A. Van Heerden, A. Atik, et al.: Intraocular lens power formula accuracy: Comparison of 7 formulas. J Cataract Refract Surg, 42(10); 2016: 1490-1500.</mixed-citation>
      </ref>
      <ref id="R7937">
        <mixed-citation>Ozcura, F., S. Aktas, H.M. Sagdik, et al.: Comparison of the biometric formulas used for applanation A-scan ultrasound biometry. Int Ophthalmol, 36(5); 2016: 707-12.</mixed-citation>
      </ref>
      <ref id="R7938">
        <mixed-citation>Mednick, Z.D., D.K. Varma, X. Campos-Moller, et al.: Refractive predictability of a 3-piece intraocular lens platform versus its 1-piece counterpart. Can J Ophthalmol, 52(2); 2017: 146-149.</mixed-citation>
      </ref>
      <ref id="R7939">
        <mixed-citation>Terzi, E., L. Wang, T. Kohnen: Accuracy of modern intraocular lens power calculation formulas in refractive lens exchange for high myopia and high hyperopia. J Cataract Refract Surg, 35(7); 2009: 1181-9.</mixed-citation>
      </ref>
      <ref id="R7940">
        <mixed-citation>Aristodemou, P., N.E. Knox Cartwright, J.M. Sparrow, et al.: Formu - la choice: Hoffer Q, Holladay 1, or SRK/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometry. J Cataract Refract Surg, 37(1); 2011: 63-71.</mixed-citation>
      </ref>
      <ref id="R7941">
        <mixed-citation>Bang, S., E. Edell, Q. Yu, et al.: Accuracy of intraocular lens calculations using the IOLMaster in eyes with long axial length and a comparison of various formulas. Ophthalmology, 118(3); 2011: 503-6.</mixed-citation>
      </ref>
      <ref id="R7942">
        <mixed-citation>Wang, J.K., C.Y. Hu, S.W. Chang: Intraocular lens power calcu - lation using the IOLMaster and various formulas in eyes with long axial length. J Cataract Refract Surg, 34(2); 2008: 262-7.</mixed-citation>
      </ref>
      <ref id="R7943">
        <mixed-citation>Zheng, Q., Z. Zhao, H. Lian, et al.: [The analysis of refractive error of long axial high myopic eyes after IOL implantation]. Zhonghua Yan Ke Za Zhi, 51(4); 2015: 276-81.</mixed-citation>
      </ref>
      <ref id="R7944">
        <mixed-citation>Long, T., Y.-S. Huang, L.-X. Xie: Refractive accuracy after intraocular lens implantation in pediatric cataract.Int J Ophthalmol , 5(4); 2012: 473-477.</mixed-citation>
      </ref>
      <ref id="R7945">
        <mixed-citation>Velika, V., Hejsek L., Raiskup F.: Klinické výsledky implantace dvou typů multifokální rotačně asymetrické nitrooční čočky. Cesk Slov Oftalmol, 73(1); 2017: 3-12.</mixed-citation>
      </ref>
      <ref id="R7946">
        <mixed-citation>Halas, M., Pesko K., Olah Z., et al.: Vplyv sferickych a asferickych umelych vnutroocnych sosoviek na kvalitu centralnej ostrosti zraku a kontrastnej citlivosti. Cesk Slov Oftalmol, 66(5); 2010: 209-12.</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>