<?xml version="1.0" encoding="UTF-8"?>
<article article-type="research-article" dtd-version="1.3" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group>
        <journal-title>Czech and Slovak Ophthalmology</journal-title>
      </journal-title-group>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id">95</article-id>
      <article-id pub-id-type="doi">10.31348/2018/5/4</article-id>
      <article-categories>
        <subj-group>
          <subject>Original article</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Pilot Results of Implantation of the New Hydrophobic Intraocular Lens Zeiss LUCIA 611P in the Czech Republic</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Stěpanov</surname>
            <given-names>Alexandr</given-names>
          </name>
          <contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-8462-8756</contrib-id>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Rozsíval</surname>
            <given-names>Pavel</given-names>
          </name>
          <contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-6628-7954</contrib-id>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Středová</surname>
            <given-names>Miroslava</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Nekolová</surname>
            <given-names>Jana</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Jirásková</surname>
            <given-names>Naďa</given-names>
          </name>
        </contrib>
      </contrib-group>
      <pub-date date-type="pub" publication-format="electronic">
        <day>27</day>
        <month>3</month>
        <year>2019</year>
      </pub-date>
      <issue>5</issue>
      <elocation-id>4</elocation-id>
      <abstract>
        <p>Background: Cataract surgery is one of the most common procedures performed by the ophthalmic surgeon. In this paper, we evaluate of postoperative results of the hydrophobic intraocular lens CT LUCIA 611 in patients undergoing routine cataract surgery. Methods: The study included 23 patients (29 eyes), average age of 69.0 + 9.2 years (span 53 to 86 years) with uncomplicated senile cataract. After phacoemulsification, CT LUCIA 611 intraocular lenses were implanted. Patients were examined 3 months and 6 months after surgery. Uncorrected visual acuity (UVA), best-corrected visual acuity (BCVA), refraction, occurrence of opacities of the posterior capsule, and subjective contentment of patients according to the questionnaire VF-14 (visual functioning) were examined. Results: 3 months after surgery, the average UVA was 0.68 ± 0.4, and BCVA 0.92 ± 0.3. Half-a-year after surgery, UVA was 0.82 ± 0.1 and BCVA 0.94 ± 0.2. Good uncorrected visual acuity and a minimal occurrence of opacities of the posterior capsule corresponded with a high degree of contentment of patients. Conclusions: On the basis of the author’s present experience it can be concluded that the Zeiss CT LUCIA 611 intraocular lens exhibits good and stable postoperative results.</p>
      </abstract>
      <kwd-group>
        <kwd>intraocular lens CT LUCIA 611</kwd>
        <kwd>posterior capsule opacity</kwd>
        <kwd>phacoemulsification</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <back>
    <ref-list>
      <title>References</title>
      <ref id="R8061">
        <mixed-citation>Adámková, H., Novák J.: Sekundární katarakta, její prevence a léčba. Část první: Prevence vzniku sekundární katarakty. Cesk Slov Oftalmol, 62(3); 2006: 230–236.</mixed-citation>
      </ref>
      <ref id="R8062">
        <mixed-citation>Bosc, JM.: Initial impressions and early clinical results of a new single-piece hydrophobic yellow acrylic IOL. Presented at the ASCRS Symposium on Cataract, IOL, and Refractive Surgery, San Francisco, 2009.</mixed-citation>
      </ref>
      <ref id="R8063">
        <mixed-citation>Jirásková, N., Rozsíval, P.: Metody hodnocení zkalení zadního pouz - dra po operaci katarakty. Cesk Slov Oftalmol, 60(2); 2004: 155–157.</mixed-citation>
      </ref>
      <ref id="R8064">
        <mixed-citation>Linnola, RJ.: The sandwich theory: a bioactivity based explanation for posterior capsule opacification after cataract surgery. J Cataract Refract Surg, 23; 1997: 1539-1542.</mixed-citation>
      </ref>
      <ref id="R8065">
        <mixed-citation>Maedel, S., Hirnschall, N., Chen, YA., et al.: Effect of heparin coating of a foldable intraocular lens on inflammation and capsular bag performance after cataract surgery. J Cataract Refract Surg, 39(12); 2013: 1810-1817.</mixed-citation>
      </ref>
      <ref id="R8066">
        <mixed-citation>Nishi, O., Yamamoto, N., Nishi, K., et al.: Contact inhibition of migrating lens epithelial cells at the capsular bend created by a sharp-edged intraocular lens after cataract surgery. J Cataract Refract Surg, 33; 2007: 1065–1070.</mixed-citation>
      </ref>
      <ref id="R8067">
        <mixed-citation>Rosca, G.: High precision injection with a new heparin coated hydrophobic one piece IOL. Presented at ASCRS, Chicago, 2012.</mixed-citation>
      </ref>
      <ref id="R8068">
        <mixed-citation>Spalton, DJ.: Posterior capsular opacification after cataract surgery. Eye (Lond), 13; 1999: 489–492.</mixed-citation>
      </ref>
      <ref id="R8069">
        <mixed-citation>Steinberg, EP., Tielsch, JM., Schein, OD., et al.: The VF-14. An index of functional impairment in patients with cataract. Arch Ophthalmol, 112(5); 1994: 630-638.</mixed-citation>
      </ref>
      <ref id="R8070">
        <mixed-citation>Wormstone, IM., Liu, CS., Rakic, JM., et al.: Human lens epithelial cell proliferation in a protein-free medium. Invest Ophthalmol Vis Sci, 38; 1997: 396–404.</mixed-citation>
      </ref>
      <ref id="R8071">
        <mixed-citation>Zemaitiene, R., Jasinskas, V., Barzdziukas, V. et al.: Prevention of posterior capsule opacification using different intraocular lenses (result of one-year clinical study). Medicina (Kaunas), 40(8); 2004: 721–730.</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>
