<?xml version="1.0" encoding="UTF-8"?>
<article article-type="research-article" dtd-version="1.3" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group>
        <journal-title>Czech and Slovak Ophthalmology</journal-title>
      </journal-title-group>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id">43</article-id>
      <article-id pub-id-type="doi">10.31348/2018/1/2-1-2018</article-id>
      <article-categories>
        <subj-group>
          <subject>Original article</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Use of EX-PRESS® implant in glaucoma surgery - retrospective study</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Fialová</surname>
            <given-names>Veronika</given-names>
          </name>
          <contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-7976-6759</contrib-id>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Váša</surname>
            <given-names>Martin</given-names>
          </name>
        </contrib>
      </contrib-group>
      <pub-date date-type="pub" publication-format="electronic">
        <day>3</day>
        <month>7</month>
        <year>2018</year>
      </pub-date>
      <issue>1</issue>
      <elocation-id>2-1-2018</elocation-id>
      <abstract>
        <p>Purpose: The objective of the study is to evaluate of primary open-angle glaucoma (POAG) with the use of EX-PRESS drainage implant. Evaluated was the decrease of intraocular pressure (IOP), visus stabilization, perimeter Humphrey - related finding (T 30-2), Heidelberg Retina Tomograph (HRT) and possibility of reducing the local drug therapy. Patients and methods: Retrospective data analysis was performed in 40 eyes with POAG in 28 subjects (14 female- and 14 male patients) average-aged 69.5 years. In all 40 eyes, surgery was performed by one surgeon within the years 2011-2017. Indications for EX-PRESS implantation in our study were the POAG with decompensated IOP, decompensated chronic secondary glaucoma or failure previously anti-glaucoma surgical operations. Within the preoperative period, in all cases the progression was observed on the perimeter T 30-2 or on the HRT. Before and after surgery, all 40 eyes were evaluated for the following factors: the IOP, visus, pachymetry, therapy by anti-glaucomatic drugs and regular inspections of the perimeter and HRT. The average post-surgery following-up time in our total of patients was 3 years and 8 months. The identified data of our total of patients were statistically processed using the Wilcoxon Signed-Rank Test. Results: The average pre-surgery IOP was 21.4 mm Hg, 6 months post-surgery 11.2 mm Hg, and 13.2 mm Hg at the last inspection. Pre-surgery anti-glaucoma therapy: monotherapy in 2 eyes, dual therapy in 25 eyes, triple therapy in 13 eyes. Post-operatively without the need of therapy were 19 eyes, the need for monotherapy in 7 eyes, dual therapy in 13-eyes and triple therapy in 1 eye. During the last inspection of the perimeter or HRT within the postoperative period, we identified stationary finding in 39 eyes and only a mild progression in 1 eye. Peroperatively, we have not identified any serious complications. Within the postoperative period, we observed choroid ablation in 10 eyes as recovered within 6-7 days. As a more serious complication, we noted endophthalmitis in 1 eye on the background of generalized lichen planus complicating skin disease. In 5 eyes within the late postoperative period we found occlusion of lateral orifices in the EX-PRESS implant by the fibrotic tissue, the 4 eyes developed cataracts, and the eyeball hypotonia persists in 1 eye at the level of 5 torr without affecting the visus of the operated eye. Conclusion: It outflows from the above results that the use of EX-PRESS implant in the surgery of glaucoma is an effective and safe method with a minimal number of complications.</p>
      </abstract>
      <kwd-group>
        <kwd>primary open-angle glaucoma</kwd>
        <kwd>filtering surgery</kwd>
        <kwd>EX-PRESS implant</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <back>
    <ref-list>
      <title>References</title>
      <ref id="R7699">
        <mixed-citation>Bing, L., Da-Dong, G., Xiu-Juan, D., et al.: Evaluation of EX-PRESS implantation combined with phacoemuldification in primary angle-closure glaucoma. Medicine (Baltimore). [online]. 2016, Sep, 96(36): e4613. [cit. 2001-01-03]. Dostupné na https://www.ncbi.nlm.nih. gov/pmc/articles/PMC5023874/.</mixed-citation>
      </ref>
      <ref id="R7700">
        <mixed-citation>Dahan, E., Carmichael, TR.: Implan - tation of a miniature glaucoma device under a scleral flap. J Glaucoma. 2005, April, 14(2) : 98-102.</mixed-citation>
      </ref>
      <ref id="R7701">
        <mixed-citation>Detorakis, E., Stojanovic, N., Chalkia, A. , et al.: EX-PRESS® Implant Position and Function: Comparative Evaluation with Ultrasound Biomicroscopy and Optical Coherence Tomography. J Ophthalmol. 2016, Jan-Mar, 23(1): 110-4.</mixed-citation>
      </ref>
      <ref id="R7702">
        <mixed-citation>EX-PRESS. Návod k obsluze zdravotnického prostředku.</mixed-citation>
      </ref>
      <ref id="R7703">
        <mixed-citation>Francis, B. A., Sarkisian, S. R. Jr., Tan, J. C.: Minimally invasive glaucoma surgery. A practical guide. New York/Stuttgart, Thieme Publishers. 2016, 236 p. ISBN 978-1-62,623-156-6.</mixed-citation>
      </ref>
      <ref id="R7704">
        <mixed-citation>Geffen, N., Trope, GE., Alasbali, T., et al.: Is the Ex-PRESS glaucoma shunt</mixed-citation>
      </ref>
      <ref id="R7705">
        <mixed-citation>Kuchynka, P. a kol.: Oční lékařství. 2. Doplněné a přepracované vydání. Praha: Grada Publishing a.s. 2016. 650s.</mixed-citation>
      </ref>
      <ref id="R7706">
        <mixed-citation>Lankaranian, D., Razeghinejad, MR., Prasad, A., et al.: Intermediate-term results of the Ex-PRESS miniature glaucoma implant under a scleral flap in previously operated eyes. Clin Exp Ophthalmol. 2011, Jul, 39(5): 421-8.</mixed-citation>
      </ref>
      <ref id="R7707">
        <mixed-citation>Leo, J., Antoine, L., Anne-Sophie, A., et al.: Five-year extension of a clinical trial comparing the EX-PRESS glaucoma filtration device and trabeculectomy in primary open-angle glaucoma. Clin Ophthalmol. 2011, 5: 527–533.</mixed-citation>
      </ref>
      <ref id="R7708">
        <mixed-citation>Mabray, M., Uzelac, A., Talbott, JE., Lin, SC., et al: Ex-PRESS glaucoma filter: an MRI compatible metallic orbital foreign body imaged at 1.5 and 3 T. Clin Radiol. 2015, May, 70(5): e28-34.</mixed-citation>
      </ref>
      <ref id="R7709">
        <mixed-citation>Mariotti, C., Dahan, E., Nicolai, M., et al.: Response to: RE: Long-term outcomes and risk factors for failure with the EX-press glaucoma drainage device. Eye (Lond). 2014, 28:1-8.</mixed-citation>
      </ref>
      <ref id="R7710">
        <mixed-citation>Marzette, L., Herndon, LW.: A comparison of the Ex-PRESS™ mini glaucoma shunt with standard trabeculectomy in the surgical treatment of glaucoma. Ophthalmic Surg Lasers Imaging. 2011, 42(6): 453-9.</mixed-citation>
      </ref>
      <ref id="R7711">
        <mixed-citation>Mlčák, P., Karhanová, M., Marešová, K.: Chirurgická léčba glaukomu. Praktické lékárenství. 2009, 5(3): 118 s.</mixed-citation>
      </ref>
      <ref id="R7712">
        <mixed-citation>Salim, S.: The role of the Ex-PRESS glaucoma filtration device in glaucoma surgery. Semin Ophthalmol. 2013, 28:180– 184.</mixed-citation>
      </ref>
      <ref id="R7713">
        <mixed-citation>Samková K., Rejmont L.: Řešení dekompenzovaného sekundárního glaukomu pomocí antiglaukomového implantátu EXPRESS. Čes a slov. Oftal. 69, 2013, 5, s.198-200.</mixed-citation>
      </ref>
      <ref id="R7714">
        <mixed-citation>Samsudin, A., Eames, I., Brocchini, S., et al.: Evaluation of Dimensional and Flow Properties of ExPress Glaucoma Drainage Devices. Journal of Glaucoma. 2016, January, Volume 25, Issue 1, pp 39–45.</mixed-citation>
      </ref>
      <ref id="R7715">
        <mixed-citation>Seibold, LK. , Rorrer, RA. , Kahook, M.: MRI of the Ex-PRESS stainless steel glaucoma drainage device. Br J Ophthalmol. 2011, Feb, 95(2): 251-4.</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>
